The MPM meter has been developed and qualified for High Pressure and High temperature (HP/HT) applications - subsea and topside.
Comprehensive full-scale testing has been conducted in full compliance with all relevant specifications and regulations. The detailed strength & FE analysis has been fully verified for the selected design solution even for the extreme design targets.

The qualification process were performed as per the DnV RP A203, for
- design pressure of 15 Kpsi (1000 bar)
- design temperature of -50 to 250 deg C
The mechanical design has further been qualified through full-size flow testing over the complete temperature and pressure range, in accordance with API / ISO specifications